Lanier 5722 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Imprimeurs Lanier 5722. Lanier 5722 User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 3
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Lanier Worldwide, Inc.
2300 Parklake Dr., N. E.
Atlanta, GA 30345-2979
Emergency Telephone: (800) 526-4371
MATERIAL SAFETY DATA SHEET
Section 1: Chemical Product and Company Information
Identity:
5722 Magenta Toner
MSDS No.
CP- 336
Product ID: 117-0327 Issued: 03/01/00
Synonyms
& Common
Names:
Uses:
Chemical
Formula:
Magenta Toner for
Lanier 5722
Lanier 5722 Full Color Digital Copier
Mixture
Supersedes:
Date:
Prepared by:
Approved by:
European
Contact:
None
03/01/00
EH&S Department 770-496-9500
Larry Choskey, Manager, CEH&S
Lanier Worldwide, Inc.
Walter Fricke, Manager, Safety &
Environment
Im Taubental D-41468 Neuss,
Germany +49-2131-387-177
Section 2: Composition / Information on Ingredients
PERCENT CAS No. EXPOSURE LIMITS SOURCE
Polyester resin Trade secret Trade secret Not listed n/a
Organic pigment Trade secret Trade secret Not listed N/a
Wax Trade secret Trade secret Not listed N/a
Silica 2 4 68909-20-6 Not listed N/a
Zinc Stearate 2 4 557-05-1 Not listed N/a
*PEL as the product: 15mg/m
3
(total dust), 5mg/m
3
(respirable dust)
*TLV as the product: 10mg/m
3
(total dust), 5mg/m
3
(respirable dust)
Section 3: Hazards Identification
HMIS Rating:
FLAMMABILITY = 1 HEALTH = 0
REACTIVITY = 0 SPECIAL = none
Health Hazards (Acute, Chronic, Immediate and Potential): Excessive inhalation may cause irritation of the nose, throat and
respiratory tract.
Health Hazards of Long Term exposure (Chronic): None
Target Organs : Prolonged breathing of high concentrations may cause
adverse effects on the respiratory system.
Medical Conditions Aggravated by Exposure to This Product : Respiratory disorders, such as asthma, may be aggravated by
prolonged exposure to high concentrations of this product.
This product contains no known hazardous materials as defined by the OSHA Hazard Communication Standard 29 CFR
1910.1200.
Section 4: First Aid Measures
Inhalation:
Remove to fresh air if effects occur. Get
medical attention if needed.
Eye Contact:
In case of contact, immediately flush
eyes with water for 15 minutes. Get
medical attention if needed.
Skin Contact: Wash with soap and water. Ingestion:
Dilute stomach contents with several
glasses of water. Get medical attention.
Section 5: Fire Fighting Measures
Suitable extinguishing media: CO
2
, dry chemical, foam, Halon or
water.
Extinguishing media which may not be used for safety
reasons: none
Avoid contact with strong oxidizers such as chromate, bromate and
nitrates.
This material will burn in case of fire. The decomposition products are CO, CO
2
, and smoke. Avoid inhalation of smoke.
Vue de la page 0
1 2 3

Résumé du contenu

Page 1 - MATERIAL SAFETY DATA SHEET

Lanier Worldwide, Inc. 2300 Parklake Dr., N. E. Atlanta, GA 30345-2979 Emergency Telephone: (800) 526-4371 MATERIAL SAFETY DATA SHEET Section 1

Page 2

MATERIAL SAFETY DATA SHEET Page 2 of CP-336 Information on this data sheet represents our current data and best opinion as to

Page 3

MATERIAL SAFETY DATA SHEET Page 3 of CP-336 Information on this data sheet represents our current data and best opinion as to

Commentaires sur ces manuels

Pas de commentaire